SECU16™

Provides 8 Low Current Relays (0.5A) as well as 8 Input channels that can be configured for analog, digital, supervised or 4-20ma.

Supervised Inputs detect broken or shorted wires, Inputs are 8 Bit A/D.

Specifications:

Size:

5.5"L x 3.25"W x 1.38"H

Power:

9-16 Volts AC or DC, 200 mA.

I/O:

8 Relay Outputs - Screw Terminals* (Form A 0.5A)
8 Input Channels - Screw Terminals*(1K Shunt or 0-5V 8-bit Analog)
ADNET©: 2 Screw Terminals (up to 14 AWG)
Power: 2 Screw Terminals (up to 14 AWG)

Click here to download the SECU16™ Manual

SECU16I™

Provides 16 Input that can be configured for analog, digital or supervised.

Supervised Inputs detect broken or shorted wires, Inputs are 8 Bit A/D.

Specifications:

Size:

5.5"L x 3.25"W x 1.38"H

Power:

9-16 Volts AC or DC, 200 mA.

Inputs:

16 Input Channels - Screw Terminals*(1K Shunt or 0-5V 8-bit Analog)
ADNET©: 2 Screw Terminals (up to 14 AWG)
Power: 2 Screw Terminals*  (up to 14 AWG)

Click here to download the SECU16I™ Manual

SECU16IR™

Provides 16 infra-red zones to control multiple IR devices such as televisions, DVD players, satellite, stereo, and VCRs. Using the zoned IR, automating your home theater is a snap!

Specifications:

Size:

5.5"L x 3.25"W x 1.38"H

Power:

9-16 Volts AC or DC, 200 mA.

I/O:

16 switched zones IR Output (accepts standard IR emitter)
ADNET©: 2 Screw Terminals (up to 14 AWG)
Power: 2 Screw Terminals (up to 14 AWG)

Click here to download the SECU16IR™ manual

RLY8XA™

Allows you to add 8 High Current Relays (240V @ 5 Amps, Form C) , and can be controlled by being hardwired to a Ocelot™ or Leopard™ II controller, or can be connected to a TW523 or PSC05 (not included) and controlled via X10 from any controller with X10 capability.

Specifications:

Size:

5.65"L x 3.75"W x 1.38"H

Power:

9 DC, 800 mA.

I/O:

Relay Outputs - Screw Terminals* (Form C, 10A)
X-10 - RJ11 Jack for TW-523 or PSC05 (Cable included)
X-10 Address - Jumper Selectable (House codes A-P)
ADNET©: 2 Screw Terminals (up to 14 AWG)
Power: 2 Screw Terminals (up to 14 AWG)

Click here to download the RLY8XA™ Manual

SpeakEasy™

Store and replay up to fifty messages. Includes a built-in amplifier, volume control, and audio line input.

Specifications:

Size:

5.5"L x 3.25"W x 1.38"H

Power:

12 Volts AC, 800 mA.

I/O:

Built-in microphone for recording voice messages.
Audio line input for recording messages from line level sources. (Computer *wav files, stereo, etc.) 
Audio line output for connection to external amplifier.
Amplified output for direct connection to 8 ohm speakers.
ADNET©: 2 Screw Terminals (up to 14 AWG)
Power: 2 Screw Terminals (up to 14 AWG)

Click here to download the SpeakEasy™ Manual